Replace failed Ceph disk on Dell hardware

We are using Dell 720 and 730xd servers for our Ceph OSD servers. Here is the process that we use in order to replace a disk and/or remove the faulty OSD from service.

In this example we will attempt to replace OSD #45 (slot #9 of this particular server):

Stop the OSD and unmount the directory:
stop ceph-osd id=45
umount /var/lib/ceph/osd/ceph-45
ceph osd crush reweight osd.num 0.0 (wait for the cluster to rebalance):
ceph osd out osd.num
service ceph stop osd.num
ceph osd crush remove osd.num
ceph auth del osd.num
ceph osd rm osd.num

megacli -PDList -a0

If not already offline…offline the drive:
megacli -pdoffline -physdrv[32:9] -a0
Mark disk as missing:
megacli -pdmarkmissing -physdrv[32:9] -a0
Permanently remove drive from array:
megacli -pdprprmv -physdrv[32:9] -a0

NOW PHYSICALLY REPLACE THE BAD THE DRIVE WITH A NEW ONE.

Set drive state to online if not already:
megacli -PDOnline -PhysDrv [32:9] -a0
Create Raid-0 array on new drive:
megacli -CfgLdAdd -r0[32:9] -a0

You may need to discard the cache before doing the last step:
First get cache lsit:
megacli -GetPreservedCacheList -a0
Clear whichover one you need to:
megacli -DiscardPreservedCache -L2 -a0

Recreate OSD using Bluestore as the new default
ceph-deploy disk zap hqosdNUM /dev/sdx
ceph-deploy osd create --data /dev/sdm hqosdNUM

Leave a Reply